Water application · Water treatment

Self-cleaning dissolved oxygen sensor for streams, lakes and long research deployments

The Agrinovo DO-130 is a dissolved oxygen probe with an automatic brush that sweeps the sensing face on a timer you set in seconds, so a deployment in a stream, lake or pond keeps a clean membrane between field visits. It reports dissolved oxygen in mg/L and water temperature in °C over RS485 Modbus RTU, takes salinity and atmospheric pressure as compensation inputs, and reads into your own logger or an Omni Genesis controller.

7 min read
Graduate student in waders kneeling on a stream bank, lowering a cable into slow green water beside a staff gauge

At a glance

Outputs
Dissolved oxygen in mg/L and temperature in °C, as float32 values
Brush interval
Set in seconds; the datasheet suggests every 2 to 4 hours in clean water
Compensation inputs
Salinity in ppt and atmospheric pressure in kPa, written over Modbus
Interface and supply
RS485 Modbus RTU at a fixed 9600 bps, 12 to 24 V DC

A dissolved oxygen record from a stream reach or a lake buoy is usually wanted for a whole season: a metabolism study, a restoration project before and after, a thesis chapter on hypoxia in a eutrophic pond. The sensor spends that season in water that grows a film on every submerged surface. The DO-130 is the Agrinovo probe built for that situation, and this page covers what it measures, how its brush is set, how to get percent saturation from its output, and when one of the other two Agrinovo DO probes is the better choice.

Why the sensing face decides the quality of a long record

Dissolved oxygen in surface water is never a constant. The USGS Water Science School describes a seasonal cycle and a daily one, with higher concentrations in cold water and lower ones in summer and autumn. The EPA stream monitoring manual places the daily low just before sunrise and the high around midday, and the EPA aquatic resource surveys note that decomposing organic matter such as an algal bloom consumes oxygen, most often near the bottom of the water column. A study of any of these needs readings every few minutes for weeks, including the hours before dawn when nobody is on site.

The same productive water fouls the instrument. A review of sensor protection by Delauney, Compère and Lehaitre reports that biofouling can disrupt measurement quality in less than a week, and lists dissolved oxygen first among the affected parameters, with turbidity, conductivity, pH and fluorescence. The USGS guidelines for continuous water-quality monitors, written for the agency’s own stations, state that the sensors need careful field inspection, cleaning and calibration, and they set out how a record is evaluated and corrected afterwards. Every correction applied to a fouled record is an assumption about what the sensor would have read. A clean membrane between visits means fewer of them.

What the DO-130 measures and outputs

The product specification lists the DO-130 as a fluorescent dissolved oxygen electrode with a replaceable membrane cap. It returns two values: dissolved oxygen concentration in mg/L and water temperature in °C. Both arrive as 32-bit floating point numbers in little-endian byte order.

Two compensation values are stored in the probe and written over Modbus:

  • Salinity, in ppt, in register 0x0062. A river station keeps one value; an estuary station can update it from a conductivity reading.
  • Atmospheric pressure, in register 0x0064, as kPa multiplied by 100. The accepted values run from 8000 to 13000, which is 80 to 130 kPa. A mountain lake and a coastal lagoon therefore get different settings.
DO-130, from the datasheet Value
Measured values Dissolved oxygen (mg/L), temperature (°C)
Data format float32, little-endian
Salinity compensation Set in ppt
Pressure compensation Set in kPa, 80 to 130 kPa accepted
Self-cleaning Automatic brush, interval set in seconds
Brush cycle Typically 3 to 5 seconds
Interface RS485 Modbus RTU, fixed 9600 bps, 8N1, CRC16
Slave address 1 to 250
Supply 12 to 24 V DC
Membrane cap Replaceable, typically after 2+ years

Setting the brush for the water you have

The brush interval lives in register 0x0014 and is written in seconds. The datasheet’s own example is 180, a sweep every three minutes. Its recommendations by environment are a reasonable starting table for field work:

Water Interval Seconds
Clean water, low biofouling Every 2 to 4 hours 7200 to 14400
Aquaculture water, moderate biofouling Every hour 3600
High density, high biofouling Every 30 minutes 1800
Wastewater, very high biofouling Every 10 to 15 minutes 600 to 900

A shaded headwater stream sits in the first row. A shallow nutrient-rich lake in July, or a pond downstream of a treatment works, is closer to the second or third. Writing 0 to register 0x0013 runs one sweep immediately, which is useful just before a comparison reading against a reference meter and for a logger that prefers to time the cleaning itself.

Getting percent saturation from mg/L

The EPA manual explains the two ways dissolved oxygen is reported. Milligrams per litre is the mass of oxygen in a litre of water. Percent saturation is that concentration relative to the maximum the water can hold at its temperature. The maximum falls as water warms: the manual’s table gives 14.60 mg/L at 0 °C, 9.07 mg/L at 20 °C and 8.24 mg/L at 25 °C, and it notes that water holds less oxygen at higher altitude.

For research use the calculation is normally done with the USGS DOTABLES method, which computes oxygen solubility from water temperature, barometric pressure and salinity using the Benson and Krause equations, and defines percent saturation as the measured concentration divided by that solubility. The DO-130 gives you the first two terms of the calculation directly, concentration and temperature, at every reading. Log barometric pressure at the site or take it from a nearby weather station, apply the solubility equation in post-processing, and the saturation series is reproducible from raw data by anyone who reads your methods section.

DO-130, DO-100 or DO-110

All three probes share the RS485 Modbus RTU interface and the 12 to 24 V DC supply. They differ in what they do about fouling, what they output and what the body is made of.

Probe Fits when From the datasheet and product page
DO-130 The probe stays in productive or sediment-laden water for weeks between visits Automatic brush, mg/L and °C, salinity and pressure compensation
DO-100 Someone visits often enough to wipe the cap, or saturation is wanted straight from the probe 0 to 20 mg/L, 0 to 200% saturation, accuracy ±2% of range, t90 about 60 seconds, IP68, 316L stainless steel body
DO-110 The water is seawater or a saline estuary 0 to 20 mg/L, IP68, titanium alloy body, salinity and pressure compensation

The DO-100 and DO-110 datasheets both instruct the user to clean the membrane cap regularly between calibrations. On the DO-130 the brush does that job.

Reading the probe from your own logger

Four wires: red to supply positive, black to ground, white to RS485 A and green to RS485 B. If your transceiver labels A and B the other way round, swap them. To read both values, request four holding registers from address 0x0000 with function 0x03. For slave address 1 the frame is 01 03 00 00 00 04 44 09, and the reply carries four bytes of oxygen followed by four bytes of temperature. The datasheet’s worked example is the byte sequence 48 E1 0A 41, which reorders to 41 0A E1 48 and decodes to 8.68 mg/L.

A probe whose address is unknown answers a read of register 0x0010 sent to the broadcast address 0xFF. The complete register map, with the calibration and brush commands, is on the DO-130 developer page.

Reading it with the Omni Genesis controller

Where there is no logger yet, the Omni Genesis reads the probe on one of its four sensor ports, set to RS485 from the cloud. The controller’s datasheet gives 4G-LTE as the default connection with Wi-Fi and Bluetooth built in, two rechargeable 18650 cells charged from a 6 to 32 V DC solar input, an IP65 enclosure, and local data logging with cloud sync. Several RS485 probes share one bus, each at its own address, so a conductivity or pH probe can sit beside the oxygen probe on the same station. Readings are exported or pulled through the interface described on the API page.

Calibration and field visits

Field calibration uses air as the reference. Place the probe in air-saturated conditions until the reading is stable, then write the atmospheric pressure, multiplied by 100, to register 0x0011. Writing to register 0x0021 restores the factory calibration. The datasheet gives a recalibration interval of 6 to 8 months under normal conditions and ties it to water type, biofouling and algae.

The brush changes how long the sensing face stays clean. Site visits still follow whatever protocol the project has adopted, and the USGS guidelines remain the reference for inspection, cleaning, calibration checks and the correction of the record. Institutions buying for a project can find quotation and purchase order details on the research purchasing page.

Agrinovo hardware for this application

Every item links to its product page with the datasheet. Specifications on those pages come from the manufacturer documents, not from this article.

Frequently asked questions

How does the DO-130 keep its membrane clean during a long deployment?

A built-in brush sweeps the sensing face automatically. You write the interval in seconds to Modbus register 0x0014, for example 180 for a sweep every three minutes or 7200 for every two hours, and you can start a single sweep on demand by writing 0 to register 0x0013. The datasheet gives a brush cycle of typically 3 to 5 seconds.

Does the DO-130 output percent saturation?

It outputs dissolved oxygen in mg/L and water temperature in °C. Percent saturation is the measured concentration divided by the oxygen solubility at that temperature, barometric pressure and salinity, so you compute it in the logger or afterwards, for example with the USGS DOTABLES equations. If you want saturation as a register on the probe itself, the DO-100 reports 0 to 200% alongside mg/L.

What brush interval should I set for a stream or a lake?

Start from the datasheet's table: every 2 to 4 hours (7200 to 14400 seconds) for clean water with low biofouling, every hour for aquaculture water, every 30 minutes at high density and every 10 to 15 minutes in wastewater. A productive pond in summer belongs nearer the hourly row than a cold upland stream does. The interval is a register, so you can change it mid-season without pulling the probe.

Can I read the DO-130 with my own data logger or microcontroller?

Yes. It is an RS485 Modbus RTU device at a fixed 9600 bps, 8 data bits, no parity, 1 stop bit, powered from 12 to 24 V DC. Reading four holding registers from address 0x0000 with function 0x03 returns dissolved oxygen and temperature as two little-endian float32 values. The full register map is on the DO-130 developer page.

How often does the DO-130 need calibration?

The datasheet says the interval depends on the water type and on the amount of biofouling and algae, and gives every 6 to 8 months under normal conditions. Field calibration is done in air: let the probe stabilise in air-saturated conditions, then write the atmospheric pressure to register 0x0011. The membrane cap is replaceable, typically after two or more years of use.

Sources

The agronomy on this page comes from the publications below. Where a number is not on this list, we left it out.

  1. Guidelines and standard procedures for continuous water-quality monitors: Station operation, record computation, and data reporting (Techniques and Methods 1-D3, 2006), R.J. Wagner, R.W. Boulger, C.J. Oblinger and B.A. Smith, U.S. Geological Survey
  2. Biofouling protection for marine environmental sensors (Ocean Science, 2010), L. Delauney, C. Compère and M. Lehaitre, Ifremer
  3. 5.2 Dissolved Oxygen and Biochemical Oxygen Demand, Volunteer Stream Monitoring: A Methods Manual, U.S. Environmental Protection Agency
  4. DOTABLES: dissolved oxygen solubility tables, U.S. Geological Survey
  5. Dissolved Oxygen and Water, Water Science School, U.S. Geological Survey
  6. Indicators: Dissolved Oxygen, National Aquatic Resource Surveys, U.S. Environmental Protection Agency

Tell us about your plot

Soil type, crop, irrigation method and what you want to see from your phone. We reply with a sensor list and a layout, not a brochure.