Water application · Water treatment
Self-cleaning dissolved oxygen sensor for streams, lakes and long research deployments
The Agrinovo DO-130 is a dissolved oxygen probe with an automatic brush that sweeps the sensing face on a timer you set in seconds, so a deployment in a stream, lake or pond keeps a clean membrane between field visits. It reports dissolved oxygen in mg/L and water temperature in °C over RS485 Modbus RTU, takes salinity and atmospheric pressure as compensation inputs, and reads into your own logger or an Omni Genesis controller.
At a glance
- Outputs
- Dissolved oxygen in mg/L and temperature in °C, as float32 values
- Brush interval
- Set in seconds; the datasheet suggests every 2 to 4 hours in clean water
- Compensation inputs
- Salinity in ppt and atmospheric pressure in kPa, written over Modbus
- Interface and supply
- RS485 Modbus RTU at a fixed 9600 bps, 12 to 24 V DC
A dissolved oxygen record from a stream reach or a lake buoy is usually wanted for a whole season: a metabolism study, a restoration project before and after, a thesis chapter on hypoxia in a eutrophic pond. The sensor spends that season in water that grows a film on every submerged surface. The DO-130 is the Agrinovo probe built for that situation, and this page covers what it measures, how its brush is set, how to get percent saturation from its output, and when one of the other two Agrinovo DO probes is the better choice.
Why the sensing face decides the quality of a long record
Dissolved oxygen in surface water is never a constant. The USGS Water Science School describes a seasonal cycle and a daily one, with higher concentrations in cold water and lower ones in summer and autumn. The EPA stream monitoring manual places the daily low just before sunrise and the high around midday, and the EPA aquatic resource surveys note that decomposing organic matter such as an algal bloom consumes oxygen, most often near the bottom of the water column. A study of any of these needs readings every few minutes for weeks, including the hours before dawn when nobody is on site.
The same productive water fouls the instrument. A review of sensor protection by Delauney, Compère and Lehaitre reports that biofouling can disrupt measurement quality in less than a week, and lists dissolved oxygen first among the affected parameters, with turbidity, conductivity, pH and fluorescence. The USGS guidelines for continuous water-quality monitors, written for the agency’s own stations, state that the sensors need careful field inspection, cleaning and calibration, and they set out how a record is evaluated and corrected afterwards. Every correction applied to a fouled record is an assumption about what the sensor would have read. A clean membrane between visits means fewer of them.
What the DO-130 measures and outputs
The product specification lists the DO-130 as a fluorescent dissolved oxygen electrode with a replaceable membrane cap. It returns two values: dissolved oxygen concentration in mg/L and water temperature in °C. Both arrive as 32-bit floating point numbers in little-endian byte order.
Two compensation values are stored in the probe and written over Modbus:
- Salinity, in ppt, in register 0x0062. A river station keeps one value; an estuary station can update it from a conductivity reading.
- Atmospheric pressure, in register 0x0064, as kPa multiplied by 100. The accepted values run from 8000 to 13000, which is 80 to 130 kPa. A mountain lake and a coastal lagoon therefore get different settings.
| DO-130, from the datasheet | Value |
|---|---|
| Measured values | Dissolved oxygen (mg/L), temperature (°C) |
| Data format | float32, little-endian |
| Salinity compensation | Set in ppt |
| Pressure compensation | Set in kPa, 80 to 130 kPa accepted |
| Self-cleaning | Automatic brush, interval set in seconds |
| Brush cycle | Typically 3 to 5 seconds |
| Interface | RS485 Modbus RTU, fixed 9600 bps, 8N1, CRC16 |
| Slave address | 1 to 250 |
| Supply | 12 to 24 V DC |
| Membrane cap | Replaceable, typically after 2+ years |
Setting the brush for the water you have
The brush interval lives in register 0x0014 and is written in seconds. The datasheet’s own example is 180, a sweep every three minutes. Its recommendations by environment are a reasonable starting table for field work:
| Water | Interval | Seconds |
|---|---|---|
| Clean water, low biofouling | Every 2 to 4 hours | 7200 to 14400 |
| Aquaculture water, moderate biofouling | Every hour | 3600 |
| High density, high biofouling | Every 30 minutes | 1800 |
| Wastewater, very high biofouling | Every 10 to 15 minutes | 600 to 900 |
A shaded headwater stream sits in the first row. A shallow nutrient-rich lake in July, or a pond downstream of a treatment works, is closer to the second or third. Writing 0 to register 0x0013 runs one sweep immediately, which is useful just before a comparison reading against a reference meter and for a logger that prefers to time the cleaning itself.
Getting percent saturation from mg/L
The EPA manual explains the two ways dissolved oxygen is reported. Milligrams per litre is the mass of oxygen in a litre of water. Percent saturation is that concentration relative to the maximum the water can hold at its temperature. The maximum falls as water warms: the manual’s table gives 14.60 mg/L at 0 °C, 9.07 mg/L at 20 °C and 8.24 mg/L at 25 °C, and it notes that water holds less oxygen at higher altitude.
For research use the calculation is normally done with the USGS DOTABLES method, which computes oxygen solubility from water temperature, barometric pressure and salinity using the Benson and Krause equations, and defines percent saturation as the measured concentration divided by that solubility. The DO-130 gives you the first two terms of the calculation directly, concentration and temperature, at every reading. Log barometric pressure at the site or take it from a nearby weather station, apply the solubility equation in post-processing, and the saturation series is reproducible from raw data by anyone who reads your methods section.
DO-130, DO-100 or DO-110
All three probes share the RS485 Modbus RTU interface and the 12 to 24 V DC supply. They differ in what they do about fouling, what they output and what the body is made of.
| Probe | Fits when | From the datasheet and product page |
|---|---|---|
| DO-130 | The probe stays in productive or sediment-laden water for weeks between visits | Automatic brush, mg/L and °C, salinity and pressure compensation |
| DO-100 | Someone visits often enough to wipe the cap, or saturation is wanted straight from the probe | 0 to 20 mg/L, 0 to 200% saturation, accuracy ±2% of range, t90 about 60 seconds, IP68, 316L stainless steel body |
| DO-110 | The water is seawater or a saline estuary | 0 to 20 mg/L, IP68, titanium alloy body, salinity and pressure compensation |
The DO-100 and DO-110 datasheets both instruct the user to clean the membrane cap regularly between calibrations. On the DO-130 the brush does that job.
Reading the probe from your own logger
Four wires: red to supply positive, black to ground, white to RS485 A and green to RS485 B. If your transceiver labels A and B the other way round, swap them. To read both values, request four holding registers from address 0x0000 with function 0x03. For slave address 1 the frame is 01 03 00 00 00 04 44 09, and the reply carries four bytes of oxygen followed by four bytes of temperature. The datasheet’s worked example is the byte sequence 48 E1 0A 41, which reorders to 41 0A E1 48 and decodes to 8.68 mg/L.
A probe whose address is unknown answers a read of register 0x0010 sent to the broadcast address 0xFF. The complete register map, with the calibration and brush commands, is on the DO-130 developer page.
Reading it with the Omni Genesis controller
Where there is no logger yet, the Omni Genesis reads the probe on one of its four sensor ports, set to RS485 from the cloud. The controller’s datasheet gives 4G-LTE as the default connection with Wi-Fi and Bluetooth built in, two rechargeable 18650 cells charged from a 6 to 32 V DC solar input, an IP65 enclosure, and local data logging with cloud sync. Several RS485 probes share one bus, each at its own address, so a conductivity or pH probe can sit beside the oxygen probe on the same station. Readings are exported or pulled through the interface described on the API page.
Calibration and field visits
Field calibration uses air as the reference. Place the probe in air-saturated conditions until the reading is stable, then write the atmospheric pressure, multiplied by 100, to register 0x0011. Writing to register 0x0021 restores the factory calibration. The datasheet gives a recalibration interval of 6 to 8 months under normal conditions and ties it to water type, biofouling and algae.
The brush changes how long the sensing face stays clean. Site visits still follow whatever protocol the project has adopted, and the USGS guidelines remain the reference for inspection, cleaning, calibration checks and the correction of the record. Institutions buying for a project can find quotation and purchase order details on the research purchasing page.
Agrinovo hardware for this application
Every item links to its product page with the datasheet. Specifications on those pages come from the manufacturer documents, not from this article.
Frequently asked questions
How does the DO-130 keep its membrane clean during a long deployment?
Does the DO-130 output percent saturation?
What brush interval should I set for a stream or a lake?
Can I read the DO-130 with my own data logger or microcontroller?
How often does the DO-130 need calibration?
Sources
The agronomy on this page comes from the publications below. Where a number is not on this list, we left it out.
- Guidelines and standard procedures for continuous water-quality monitors: Station operation, record computation, and data reporting (Techniques and Methods 1-D3, 2006), R.J. Wagner, R.W. Boulger, C.J. Oblinger and B.A. Smith, U.S. Geological Survey
- Biofouling protection for marine environmental sensors (Ocean Science, 2010), L. Delauney, C. Compère and M. Lehaitre, Ifremer
- 5.2 Dissolved Oxygen and Biochemical Oxygen Demand, Volunteer Stream Monitoring: A Methods Manual, U.S. Environmental Protection Agency
- DOTABLES: dissolved oxygen solubility tables, U.S. Geological Survey
- Dissolved Oxygen and Water, Water Science School, U.S. Geological Survey
- Indicators: Dissolved Oxygen, National Aquatic Resource Surveys, U.S. Environmental Protection Agency
Other applications
Water treatment
Nitrate in groundwater and runoff
How the Agrinovo NO3-100 nitrate probe is used in wells, streams and runoff studies: what it reports, the 30 mg/L working range, chloride and calibration.
Orchards & plantations
Avocado orchards
Which sensors an avocado orchard needs and where to put them: tensiometers and Watermark probes at 20 and 45 cm, irrigation triggers by soil type, EC of the irrigation water, and the Agrinovo hardware that reads them remotely.
Orchards & plantations
Citrus orchards
Which sensors a citrus grove needs and where they go: two soil water sensors in the top 30 cm at the dripline, depletion and tension triggers, irrigation water EC against rootstock chloride limits, and the Agrinovo hardware.
Tell us about your plot
Soil type, crop, irrigation method and what you want to see from your phone. We reply with a sensor list and a layout, not a brochure.