pH Sensors and pH Probes

High-precision pH sensors and probes for aquaculture water quality monitoring. Industrial-grade water quality sensors with long-term stability and wide measurement range. Essential for maintaining optimal pH levels in fish farms and aquaculture operations.

How to choose a pH probe

A pH probe and a pH sensor are the same instrument: the electrode that is immersed in the water or mounted in a pipe. The Agrinovo range splits by output signal first and by the liquid second. Start from what will read the probe, then check the process conditions.

ModelOutputRange and accuracyChoose it for
PH-100 RS485 Modbus RTU0.00 to 14.00 pH, ±0.02 pHFreshwater monitoring with a digital signal
PH-110 RS485 Modbus RTU or analog (0-2 V, 0-5 V, 0-10 V, 4-20 mA), chosen at order0 to 14.00 pH, ±0.02 pHSeawater, and controllers or PLCs that need an analog input
PH-10 Analog-2.00 to 16.00 pH, ±0.01 pHIn-line mounting (PG13.5 thread) on an existing pH transmitter
PH-G10 Analog-2.00 to 16.00 pH, ±0.01 pHHot liquids, 0 to 110°C
PH-T10 Analog-2.00 to 16.00 pH, ±0.01 pHFlue gas desulfurization lines

Digital or analog

A digital pH probe converts the signal inside the probe and sends a finished reading over RS485, so cable length and electrical noise matter far less and several probes can share one cable. An analog pH electrode sends the raw electrode signal and needs a transmitter or controller input built for it.

All five are rated IP68. The digital models connect to an Omni Genesis controller with other water quality sensors on the same bus. For the trade-offs in detail, read the RS485 pH sensor selection guide.

pH probe questions

Is a pH probe the same as a pH sensor?

Yes. Both names describe the electrode that sits in the liquid. "pH meter" usually means the instrument with a display that the probe plugs into.

Which pH probe works with a PLC?

The PH-110 is ordered with an analog output (0-2 V, 0-5 V, 0-10 V or 4-20 mA) or with RS485 Modbus RTU, so the analog version fits a standard analog input. The PH-100 suits any controller that reads Modbus RTU.

Which pH probe should I use in seawater?

The PH-110. The PH-100 is the freshwater model.

Do these probes compensate for temperature?

Calibrate the PH-100 and PH-110 close to the temperature of the water they measure. On the analog PH-10 the PT1000 is optional, and the PH-G10 and PH-T10 include it.