Drying Room Monitoring and Humidity Control

A drying room is won or lost on humidity. Agrinovo measures temperature and relative humidity continuously, alerts the moment either leaves the band you set, and switches your fans, heater and dehumidifier through the controller. Used for cannabis, dates, herbs and seeds.

Measure both variables, then act on them

Recording a bad dry is not the same as preventing one. The controller does both.

±0.3°C
Temperature accuracy
±3% RH
Humidity accuracy
4
Relay outputs per controller
RS-485
Modbus RTU sensor bus

One bad night costs the batch

Humidity climbing overnight is the failure nobody sees until the room is opened. Continuous logging plus an alert on the first reading outside the band turns that into a phone notification instead of a loss.

A record of every batch

Every reading is stored and exportable, so each batch carries a full temperature and humidity history. Useful for proving process consistency and for working out why one run came out better than another.

Rooms are not uniform

Temperature and humidity vary between floor and ceiling, and near the extraction point. Sensors are addressable on the Modbus bus, so a room can carry several measurement points rather than one and a hope.

Control that survives an outage

The control loop runs on the controller itself, not in the cloud. If connectivity drops, the relays keep working to your setpoints and the readings sync when the link returns.

How the control loop works

Four parts, wired once.

  1. 01

    Sense

    A THS-100 temperature and humidity sensor reports over RS-485 Modbus RTU. Probe housings are available for high dust and washdown environments.

  2. 02

    Decide

    The Omni Genesis controller compares each reading against your setpoint and hysteresis band, so equipment does not chatter on and off around the threshold.

  3. 03

    Act

    Up to four relay outputs switch the extraction fan, dehumidifier, humidifier and heater. Each output has its own rule.

  4. 04

    Log and alert

    Readings stream to the cloud dashboard, and anything outside the band raises an alert. History is exportable per room and per batch.

For the wiring detail, setpoint and hysteresis walkthrough, see the drying room humidity control guide.

What gets dried in these rooms

Same hardware, different targets.

Cannabis

Drying and curing rooms, where a narrow humidity band over a long hold decides the quality of the batch.

Dates

Hydration and drying rooms, where the target moves through the cycle rather than staying fixed.

Herbs and spices

Low temperature drying where overshooting costs colour and aroma.

Seeds and grain

Drying to a storage moisture target, then holding it without over-drying.

Technical specifications

Temperature range-40 to +80°C
Temperature accuracy±0.3°C at 25°C
Humidity range0 to 100% RH, non-condensing
Humidity accuracy±3% RH at 60% RH, 25°C
Response time≤15 s temperature, ≤4 s humidity at 1 m/s airflow
Long-term stability≤0.1°C/year, ≤1% RH/year
Sensor outputRS-485, Modbus RTU
Controller outputsUp to 4 independent relays
Probe housingsVented, sealed, brass, stainless, sintered, IP67

Talk to us about your drying rooms

Tell us how many rooms you run and what you dry, and we will scope the system with you.

Send a message instead

Stop guessing at the room

Put a number on temperature and humidity, and an alert on the moment either drifts.

Technical capabilities

The facts an integration plan needs. Full measurement range and accuracy specifications are on every product page and datasheet.

Sensor protocols

  • RS-485 Modbus RTU
  • SDI-12
  • I2C
  • Analog
  • 1-Wire

Connectivity

  • 4G LTE cellular (optional)
  • Wi-Fi
  • Bluetooth

Power and enclosure

  • Solar powered
  • Battery operated, deep-sleep cycle
  • IP65 rated controllers

Data and integration

  • Cloud dashboard with real-time alerts
  • Configurable reporting intervals
  • REST API access