Continuous monitoring for water and wastewater treatment
Agrinovo puts sensors at each control point of a treatment line, from disinfection residual to aeration oxygen, sludge concentration and effluent quality. Every reading reaches the dashboard and the operators' phones around the clock, through a cellular controller that runs on mains, batteries or solar.
Where a treatment line needs a reading, not a grab sample
A laboratory sample tells you what the water was when it was taken. A sensor in the water tells you what it is now, and what it did overnight. Three points on most treatment lines decide whether the plant is in control.
Disinfection residual
Too little ozone or chlorine dioxide and the water is under-treated; too much and you waste oxidant and risk exceeding a limit. In US drinking water, for example, the EPA sets a maximum residual disinfectant level of 0.8 mg/L for chlorine dioxide and a limit of 1.0 mg/L for its by-product chlorite. The O3-100 reads dissolved ozone from 0.00 to 20.00 mg/L (±0.02 mg/L) and the ClO2-100 reads chlorine dioxide from 0.00 to 20.00 mg/L (±0.1 mg/L), with the ORP-110 as the fast indicator beside them.
Aeration and nutrient removal
Aeration is usually the largest energy user in a plant: the US EPA, citing the Water Environment Federation, puts it at 25 to as much as 60 percent of total plant energy use, and EPA training material gives 1.0 to 2.0 mg/L as the desired average oxygen in most activated sludge reactors. A self-cleaning DO-130 oxygen probe in the basin, ammonium and nitrate electrodes, and the MLSS-110 sludge sensor (0 to 50,000 mg/L) give the operator the numbers that air and sludge decisions are made on.
Effluent and reuse
The COD-130 reads COD by UV absorption (0-300 or 0-1500 mg/L) and also reports BOD, TOC and turbidity values, the TUR-110 reads 0.01 to 3000 NTU, and the SS-130 reads suspended solids. Where treated water goes to irrigation, conductivity, pH, nitrate and chloride follow it to the reservoir. The FAO guidelines for irrigation water quality start restricting use at a conductivity of 0.7 dS/m.
How a treatment monitoring point is installed
-
A sensor at the point of control
Immersed in the basin or contact tank on a bracket, or fitted into the pipe. The COD, turbidity, suspended solids, sludge and oxygen sensors clean themselves with an automatic wiper or brush, for basins nobody wants to clean by hand, and the cable runs to a controller mounted at a dry, safe spot.
-
A controller that reports on its own
The Omni Genesis reads up to four sensors and sends every reading over the cellular network, on mains, batteries or solar, so a pump station, a reservoir or a small plant needs no network or control room. Where the plant already has a control system, the same sensors can report into it as well; your control contractor will find the technical details on our integration page.
-
A range and a delay for each point
On the dashboard each probe gets a name, a minimum, a maximum and the time a reading may stay outside them before an alert opens, so a short spike during backwashing or a cleaning cycle does not raise one.
Guides: dissolved ozone monitoring · chlorine dioxide monitoring · COD and suspended solids · cooling tower corrosion
What you see and when you hear about it
Every point on one screen
Each probe appears with its current reading, its range and its history, grouped by site, so a plant, its pump stations and its reuse reservoir sit on the same dashboard.
An alert that keeps asking
When a reading stays out of range longer than allowed, the users on the account get an app notification. It repeats every two hours by default until someone reads it, a second notice follows when the reading is back in range, and a probe marked as critical comes through quiet hours.
A failed probe is not a good reading
The controller reports a disconnected or short-circuited sensor as a fault instead of a plausible number, an offline alert opens if a controller stops reporting, and a low battery raises its own alert. Rules on the controller can also switch a valve or a dosing pump through a relay, and keep working if the connection drops.
Where it is installed
Small and rural wastewater plants
Aeration oxygen, sludge concentration and effluent quality at plants without a full-time operator on site.
Ozone and chlorine dioxide disinfection
Residual control in drinking water, food and beverage plants, aquaculture recirculation and process water.
Treated wastewater for irrigation
Conductivity, pH, nitrate, ammonium, chloride and turbidity at the reservoir and the farm inlet.
Industrial effluent and pretreatment
COD, suspended solids, pH and flow before discharge to a sewer or a receiving water.
Cooling towers and process water
Conductivity, pH, ORP and corrosion rate on cooling and process loops.
Pump stations and remote reservoirs
Sites with no network and often no mains power, on a cellular controller with batteries and solar.
Probes for treatment monitoring
| Dissolved ozone (O3-100) | 0.00-20.00 mg/L, ±0.02 mg/L, IP68 |
|---|---|
| Chlorine dioxide (ClO2-100) | 0.00-20.00 mg/L, ±0.1 mg/L, electrochemical |
| ORP (ORP-110) | -1999 to +1999 mV, ±3 mV, PTFE body, IP68 |
| Dissolved oxygen (DO-130) | Fluorescent, automatic cleaning brush, salinity and pressure compensation |
| Sludge and suspended solids (MLSS-110, SS-130) | 0-50000 mg/L, ±10% or 10 mg/L, self-cleaning, IP68 (MLSS-110) |
| COD (COD-130) | UV absorption, 0-300 or 0-1500 mg/L, ±10%, also BOD, TOC and turbidity values, self-cleaning |
| Turbidity (TUR-110) | 0.01-3000 NTU, ±5% or ±0.5 NTU, self-cleaning, IP68 |
| Ammonium, nitrate, chloride (NH4-100, NO3-100, Cl-100) | Ion-selective electrodes, ±5% F.S. |
| pH and conductivity (PH-110, EC-100) | pH 0-14.00, ±0.02 pH; conductivity 0.2 µS/cm to 100 mS/cm, ±1.0% F.S. |
| Flow (EMF-200) | Insertion electromagnetic, DN100-DN3000, ±1.5% of reading at ≥1 m/s |
| Reporting | Omni Genesis over the cellular network, dashboard and phone alerts; can also feed an existing control system |
Questions about treatment monitoring
Can sensors in the water replace laboratory tests?
Which parameters matter in an activated sludge basin?
How is ozone or chlorine dioxide residual monitored continuously?
What should treated wastewater for irrigation be checked for?
Can the readings also go into our existing control system?
Can the system run at a remote site without power?
Tell us about your treatment line
What the plant treats, which points you need to watch, whether there is a control system on site, and who should get the alert. We will match the sensors to the points.