ORP-110 Industrial ORP Probe - RS485 Modbus - Industrial ORP probe with RS485 Modbus output. PTFE body, four-layer isolation, IP68 rating, 3/4-inch NPT mount on both ends, single-point offset calibration.
ORP probesavailable

ORP-110 Industrial ORP Probe - RS485 Modbus

Industrial ORP probe with RS485 Modbus output. PTFE body, four-layer isolation, IP68 rating, 3/4-inch NPT mount on both ends, single-point offset calibration.

Contact for pricing

Share:
SKU:AGRINOVO-ORP-110
Model:ORP-110
Shipping Weight:0.5 kg

Product Highlights

View all in Specifications tab
Sensor Type:Industrial ORP Probe
Measurement Range:-1999 to +1999 mV
Resolution:1 mV

Overview

The ORP-110 is an industrial ORP (oxidation-reduction potential) probe designed for continuous water quality measurement and control. Its RS485 Modbus RTU output connects directly to IoT controllers and any PLC or SCADA system that speaks Modbus. Internal axial capacitor filtering, a 100MΩ high-impedance front end, and four-layer isolation give it the noise immunity needed for disinfection lines, greenhouses, and process water, and the PTFE electrode body with IP68 sealing holds up in continuous immersion.

Key Features

  • Full ORP range: -1999 to +1999 mV at 1 mV resolution, ±3 mV accuracy
  • Digital output: RS485 Modbus RTU, multi-drop bus wiring
  • Noise immunity: axial capacitor filtering, 100MΩ impedance, four-layer isolation
  • Built for immersion: PTFE body, IP68 rating, stability of 2 mV or better per 24 hours
  • Easy mounting: 3/4” NPT thread on both ends for inline or submersion installs
  • Simple calibration: single-point offset against a standard solution, over the bus

Why Monitor ORP

ORP summarizes the oxidizing or reducing state of water in one live number. In aquaculture and RAS it tracks disinfection strength and organic load; in irrigation and fertigation lines it verifies water treatment; in wastewater it monitors process stages. Because ORP responds within seconds to dosing changes, a continuous probe paired with alerts catches over- and under-dosing that spot checks miss.

Installation

Mount inline via the front or back 3/4” NPT thread, or submerge the probe directly; avoid trapped air bubbles at the electrode in pipeline installs. Keep the electrode wet between uses and clean it gently; the PTFE body tolerates continuous immersion in demanding water. Calibration is a single-point offset against an ORP standard solution, written over RS485 without removing the probe for long.

Connectivity and Integration

The RS485 Modbus RTU output (9600 bps, 8-N-1) connects directly to the Omni Genesis and Genesis Lite controllers, streaming continuous ORP readings to the cloud with thresholds and alerts, and connects to any PLC or dosing controller with a Modbus RTU input. This is the same modular approach as the rest of the Agrinovo range: one controller, any mix of sensors, including the PH-110 sharing the same industrial body.