# AGRINOVO-ORP-110: Industrial ORP Sensor

Agrinovo technical datasheet, revision 1.2 (October 2026).
PDF version: https://agrinovo.io/datasheets/sensors/AGRINOVO-ORP-110_Datasheet.pdf

## 1. Overview

The AGRINOVO-ORP-110 is an intelligent industrial ORP (oxidation-reduction potential) sensor designed for continuous measurement and control of water quality. It features enhanced stability with internal axial capacitor filtering and 100MΩ input impedance, four-layer isolation for interference resistance, a PTFE-bodied electrode, and an IP68 waterproof rating.

### Key Features

- ORP range: -1999 to +1999 mV
- Accuracy: ±3 mV
- Resolution: 1 mV
- IP68 waterproof
- Four-layer isolation
- 100MΩ high impedance
- RS485 Modbus-RTU output
- 3/4" NPT mounting, both ends

### Applications

- Agricultural irrigation and fertigation
- Aquaculture and RAS disinfection control
- Greenhouses and hydroponics
- Sewage and process water treatment
- Environmental monitoring

## 2. Specifications

| Parameter | Specification |
|:----------|:--------------|
| **Measurement Range** | -1999 to +1999 mV |
| **Resolution** | 1 mV |
| **Accuracy** | ±3 mV |
| **Stability** | ≤2 mV / 24 hours |
| **Power Consumption** | ≤0.5W |
| **Protection Rating** | IP68 |
| **Operating Temp** | 0-60°C |
| **Operating Humidity** | ≤85% RH |
| **Electrode Body** | PTFE |

## 3. Physical Dimensions

| Parameter | Dimension |
|:----------|:----------|
| **Total Length** | 160 mm |
| **Probe Diameter** | 28 mm |
| **Mounting Thread** | 3/4" NPT, front and back |
| **Probe Head** | 50 mm |
| **Body** | 90 mm |
| **Tail** | 20 mm |

## 4. Electrical Characteristics

| Output Type | Supply Voltage |
|:------------|:---------------|
| RS485 | 7-24 VDC |

## 5. Wiring

| Wire Color | Function | Description |
|:-----------|:---------|:------------|
| **Red** | V+ | Power (7-24V DC) |
| **Black** | GND | Power Ground |
| **Yellow** | RS485-A | Data+ |
| **Green** | RS485-B | Data- |

## 6. Communication Settings

| Parameter | Value |
|:----------|:------|
| **Protocol** | Modbus-RTU |
| **Baud Rate** | 9600 bps |
| **Data Bits** | 8 |
| **Parity** | None |
| **Stop Bits** | 1 |
| **Default Address** | 0x01 |

## 7. Register Map

### Measurement Registers (Function 0x03)

| Address | Description | Scaling |
|:--------|:------------|:--------|
| 0x0000 | ORP Value | Direct (mV), two's complement for negative values |

### Configuration Registers (Function 0x06)

| Address | Description | Notes |
|:--------|:------------|:------|
| 0x000A | Intercept/Offset | Direct (mV), two's complement for negative values |
| 0x0050 | Slave Address | 0x01-0xFE; broadcast 0xFE with one device connected |

## 8. Calibration

The ORP-110 uses single-point offset calibration. Place the cleaned sensor in an ORP standard solution (for example +220 mV), read the sensor value, and write the difference to the offset register 0x000A: a positive correction as the plain hex value, a negative correction in two's complement. Example: reading +200 mV against a +220 mV standard requires a +20 mV offset, written as 0x0014.

## Ordering Information

| Part number | Description |
|:------------|:------------|
| AGRINOVO-ORP-110 | Industrial ORP Sensor |

## Revision History

| Rev | Date | Changes |
|:----|:-----|:--------|
| 1.0 | June 2026 | Initial release |
| 1.1 | August 2026 | Layout revision |
| 1.2 | October 2026 | New layout |

## Contact

Agrinovo, https://agrinovo.io/products, contact@agrinovo.io, +972 54 688 8148 (direct / WhatsApp).
Specifications subject to change without notice.