Cold room and cold storage temperature monitoring

Agrinovo installs temperature and humidity sensors at several points in each cold room, connects them to a controller mounted outside the room, and sends an alert when any point stays out of its range longer than you allow.

A cold room needs more than one measuring point

The air near the door warms every time it opens, the air at the evaporator is the coldest in the room, and warm spots form in the far corner behind stacked pallets. A reading from one point describes that point only, while an inspector or a customer asks about the whole room.

An open door shows up first on the sensor beside it

Unloading a truck takes a few minutes, a door left open takes an hour. You set how long each point may stay out of range, so routine unloading raises no alert and a door left open does.

An icing evaporator shows as a slow rise over several days

The room history shows the trend before the first alert fires. That is the time to schedule a defrost or call a technician.

One controller reads several points in several rooms

Temperature and humidity sensors share one RS-485 cable, each with its own address, so a controller outside the rooms reads several points in several rooms. Each point has its own name, range and history.

Complete systems for this application

We connect the sensors to the controller and configure the dashboard and alerts before the system ships.

Cold room and refrigerator monitoring

Temperature readings from each fridge, freezer or cold room, an alert when one leaves its range, and a stored record for inspections.

Measures
Temperature, and humidity where it matters
Controller
Genesis Lite for one fridge, Genesis for up to four points
Alerts
Out of range longer than you allow, disconnected probe
Sensor details

Sensors: Temperature, and humidity where it matters, with the probe chosen for your range, from display fridge to freezer.

Controller: Omni Genesis Lite for one fridge, Omni Genesis for up to four points, Omni Exodus or expansion for more.

Ask for a quote on WhatsApp

What we do before and after delivery

We connect the sensors to the controller and register them before shipping.

We set up the dashboard and configure the alerts with you in the cloud. You can change them at any time.

The cloud subscription is included, with a cellular SIM on 4G controllers.

After delivery we hold a remote onboarding call. In Israel we also install on site.

How it is installed

  1. Sensors inside the room

    A temperature and humidity sensor near the door and another in the far corner, on one RS-485 cable. For a freezer room, or to measure inside the product, a stainless temperature probe rated down to -55°C.

  2. The controller on the outside wall

    The Omni Genesis is mounted outside the room, at normal temperature. The sensor cable enters through an existing pass-through or a small sealed hole. The controller reports over cellular or Wi-Fi and keeps measuring on its battery during a power cut.

  3. A range for each point

    Each point gets a name, a minimum, a maximum and an allowed time out of range: 0 to 2°C for a meat room, 4 to 8°C for vegetables, below -18°C for frozen goods. The controller reports as often as you choose, down to once a minute.

For individual refrigerators and freezers in a kitchen or shop, see refrigerator and freezer temperature monitoring.

What you see and when you are alerted

Live readings

The current temperature, and humidity where it is measured, at every point, grouped by room.

Alarms

When a point stays out of range longer than allowed, a temperature alarm goes to every user on the account by SMS, email, phone call or app notification.

Records for inspections

Every reading is stored with its time. You export any room and period to Excel for an inspection or a dispute over a warm delivery.

Alerts about the system itself

A disconnected sensor, a controller that has stopped reporting and a low battery each raise their own alert, so a room with no new readings is never taken for a room in range.

Where it is installed

Cold storage and distribution

Several rooms at different temperatures on one controller, with a history per room.

Freezer rooms

A stainless probe rated down to -55°C, and an allowed time out of range that covers a scheduled defrost.

Packing houses and pre-cooling

Produce is cooled after harvest, and the time it takes to reach the target temperature decides its shelf life. Temperature and humidity are measured together.

Ripening rooms

Bananas, avocados and mangoes, where relative humidity matters as much as temperature. One sensor measures both.

Walk-in coolers and freezers

The walk-in of a restaurant, a butcher or a supermarket takes the same sensors, with the controller on the wall outside the box. Reach-in fridges on the same site are covered by a fridge temperature monitoring system with a probe in each cabinet.

Food factories and central kitchens

Raw material rooms and finished goods rooms, each one a control point in the HACCP plan. See food factory temperature monitoring.

Specifications

Temperature and humidity sensor -40 to +80°C, ±0.3°C at 25°C; 0-100% RH, ±3% RH
Sensor housings Vented, sealed, brass, stainless or sintered, up to IP67
Sensor cable RS-485 Modbus RTU, several addressed sensors on one cable
Temperature probe -55 to +125°C, ±0.5°C (-10 to +85°C), IP68
Controller Omni Genesis: 4 ports, rechargeable battery, 6-32 V DC input, IP65 enclosure
Connectivity 4G-LTE with SIM included, Wi-Fi, Bluetooth
Reporting interval Your choice, from once a minute
Export Excel, per sensor and per period
Warranty 24 months on the controller

Questions about cold room temperature monitoring

What does a cold storage temperature monitoring system include?

It has three parts: temperature and humidity sensors inside each cold room, walk-in cooler or freezer room; an Omni Genesis controller on the wall outside, which reads the sensors and reports over the cellular network; and the OmniCloud dashboard and phone app, where each point has its range, its alarm and its stored history. The same system covers a single walk-in and a cold storage warehouse with many rooms, and only the number of measuring points changes.

How many measuring points does one cold room need?

A small room needs one point, away from the door and the evaporator. A room of several tens of square metres needs at least two, one near the door and one in the far corner, because the difference between them is what an inspector asks about. The temperature and humidity sensors are addressed on an RS-485 cable, so several sensors in one room use a single controller port.

How does the cable get into the room?

Through an existing pipe pass-through in the panel, or a small hole drilled and sealed after the cable is pulled. The controller stays outside at normal temperature and only the sensors are inside.

Does the warehouse need Wi-Fi?

No. The system is wired inside the room and wireless outside it: the controller reports over the cellular network with a SIM included in the cloud subscription, which also works where metal-faced panels block wireless signals. Wi-Fi can be used where a stable network reaches the controller.

What happens in a power outage?

The controller runs on a rechargeable battery, so it keeps measuring, storing readings and sending alerts. Afterwards the history shows when the room started to warm and how fast.

Can humidity be monitored as well?

Yes. The temperature and humidity sensor measures both at the same point, from -40 to +80°C and 0 to 100% RH. In ripening rooms, pre-cooling rooms and vegetable cold stores, humidity affects shelf life as much as temperature.

How does the cold room temperature alarm work?

Each measuring point has a low limit, a high limit and a delay. When a reading stays outside the limits longer than the delay, an alarm goes to the users on the account and repeats until someone reads it, every two hours by default. A point marked as critical comes through a user's quiet hours, and a second notification follows when the room is back in range. Choosing the limits and delays is covered in the guide to setting cold storage temperature alarms.

What temperature should a cold room or cold store be kept at?

The product sets the range. US guidance puts refrigerated food at or below 4°C (40°F) and frozen food at -18°C (0°F) (FDA). In England, food that needs chilling for safety may not be kept above 8°C (Food Safety and Hygiene Regulations 2013, Schedule 4), and in Australia potentially hazardous food is kept at 5°C or colder (FSANZ, Standard 3.2.2). Set the alarm limit a little inside your product limit, so the alarm leaves time to act.

Is a data logger enough for a cold room?

A data logger records the temperature and someone downloads it later, so it documents an excursion after the product is already warm. That is enough for a small room that staff check every shift. A room that runs unattended at night, or holds a full load, needs an alarm while it is happening. The guide to data loggers and real-time monitoring for cold rooms sets out where each one fits.

Can the records be used for HACCP and food safety audits?

Every reading is stored with its time for each measuring point, with no gaps from missed manual checks, and any room and period exports to Excel. What a HACCP plan asks of temperature records is covered in the guide to temperature monitoring for food safety and HACCP.

Can one account cover several cold stores?

Yes. Each site has one or more controllers and all of them report into the same account, so every room on every site appears on one dashboard with its own range, alarm and history.

Tell us about your cold store

How many rooms, at which temperatures, and where the controller can be mounted. We will plan the measuring points with you.