EC-120 with Arduino, ESP32, Raspberry Pi and Python
How to wire the EC-120 High Conductivity Digital Probe to your own microcontroller or computer and read it over RS485 Modbus RTU. The tables are the ones in the datasheet, and both code examples are run against the datasheet example frame before this page is published.
Connecting the EC-120
The probe is an RS485 device, so it needs a transceiver between it and your board. On a computer or a Raspberry Pi that is a USB to RS485 adapter. On a microcontroller it is a MAX485-type module on a hardware serial port. Power the probe from a supply within the voltage range in the table and join its ground to the ground of the transceiver.
| Wire Color | Function | Description |
|---|---|---|
| Red | V+ | Power Supply (7 to 24 VDC) |
| Black | GND | Power Ground |
| Yellow | RS485-A | Data+ |
| Green | RS485-B | Data- |
| White | 4 to 20mA+ | Analog Current Output |
to 20mA Loop Load
| Supply Voltage | Maximum Load |
|---|---|
| 12 V | 250 Ω |
| 20 V | 500 Ω |
| 24 V | >500 Ω |
Python example (Raspberry Pi, Linux, macOS, Windows)
The script needs only pyserial. It builds the Modbus request itself, checks the CRC of the reply and prints one reading every five seconds. On Windows pass the COM port as the argument.
#!/usr/bin/env python3
"""Read the Agrinovo EC-120 over RS485 Modbus RTU.
Works on a Raspberry Pi or any computer with a USB to RS485 adapter.
Install the serial library once: pip install pyserial
Run: python3 ec_120.py /dev/ttyUSB0
"""
import struct
import sys
import time
import serial
PORT = sys.argv[1] if len(sys.argv) > 1 else "/dev/ttyUSB0"
ADDRESS = 0x01 # the probe's Modbus address
def crc16(frame: bytes) -> bytes:
crc = 0xFFFF
for byte in frame:
crc ^= byte
for _ in range(8):
crc = (crc >> 1) ^ 0xA001 if crc & 1 else crc >> 1
return struct.pack("<H", crc)
def read_registers(port, address, function, start, count):
request = struct.pack(">BBHH", address, function, start, count)
port.reset_input_buffer()
port.write(request + crc16(request))
reply = port.read(5 + 2 * count)
if len(reply) >= 5 and reply[1] == function | 0x80:
raise IOError(f"probe returned Modbus error {reply[2]}")
if len(reply) != 5 + 2 * count or crc16(reply[:-2]) != reply[-2:]:
raise IOError("no valid reply from the probe")
return reply[3:-2]
def read_probe(port):
data = read_registers(port, ADDRESS, 0x03, 0x0000, 10)
return {
"conductivity_ms_cm": struct.unpack(">f", data[2:4] + data[0:2])[0],
"resistivity_ohm_cm": struct.unpack(">f", data[6:8] + data[4:6])[0],
"temperature_c": struct.unpack(">f", data[10:12] + data[8:10])[0],
"tds_ppm": struct.unpack(">f", data[14:16] + data[12:14])[0],
"salinity_ppm": struct.unpack(">f", data[18:20] + data[16:18])[0],
}
if __name__ == "__main__":
with serial.Serial(PORT, 9600, bytesize=8, parity="N", stopbits=1, timeout=1) as port:
while True:
print(read_probe(port))
time.sleep(5) Arduino example (ESP32, Mega and other boards with a second serial port)
The sketch uses no library. On an ESP32 it uses Serial2 on the pins set at the top; on AVR boards it uses Serial1. DE and RE of the transceiver go to one output pin.
// Agrinovo EC-120 over RS485 Modbus RTU.
// For a board with a spare hardware serial port (ESP32, Mega, Leonardo, Due)
// and a MAX485-type transceiver. Power the probe from its own supply, as the
// wiring table says, and join the grounds.
const uint8_t ADDRESS = 0x01; // the probe's Modbus address
const int DE_PIN = 4; // transceiver DE and RE tied together
const int RX_PIN = 16; // ESP32 only
const int TX_PIN = 17; // ESP32 only
#if defined(ESP32)
#define RS485 Serial2
#else
#define RS485 Serial1
#endif
uint16_t crc16(const uint8_t *frame, size_t length) {
uint16_t crc = 0xFFFF;
for (size_t i = 0; i < length; i++) {
crc ^= frame[i];
for (int bit = 0; bit < 8; bit++) {
crc = (crc & 1) ? (crc >> 1) ^ 0xA001 : crc >> 1;
}
}
return crc;
}
// Builds a float from its four bytes, most significant first.
float float32(uint8_t b3, uint8_t b2, uint8_t b1, uint8_t b0) {
uint32_t bits = ((uint32_t)b3 << 24) | ((uint32_t)b2 << 16) | ((uint32_t)b1 << 8) | b0;
float value;
memcpy(&value, &bits, sizeof value);
return value;
}
// Reads `count` registers into `data`. Returns false when the probe does not
// answer or the checksum is wrong.
bool readRegisters(uint8_t function, uint16_t start, uint16_t count, uint8_t *data) {
uint8_t request[8] = {ADDRESS, function, (uint8_t)(start >> 8), (uint8_t)start,
(uint8_t)(count >> 8), (uint8_t)count, 0, 0};
uint16_t crc = crc16(request, 6);
request[6] = crc & 0xFF;
request[7] = crc >> 8;
while (RS485.available()) RS485.read();
digitalWrite(DE_PIN, HIGH);
RS485.write(request, 8);
RS485.flush();
digitalWrite(DE_PIN, LOW);
uint8_t reply[5 + 2 * 16];
size_t expected = 5 + 2 * count;
if (RS485.readBytes(reply, expected) != expected) return false;
uint16_t received = reply[expected - 2] | ((uint16_t)reply[expected - 1] << 8);
if (reply[1] != function || crc16(reply, expected - 2) != received) return false;
memcpy(data, reply + 3, 2 * count);
return true;
}
void setup() {
Serial.begin(115200);
pinMode(DE_PIN, OUTPUT);
digitalWrite(DE_PIN, LOW);
#if defined(ESP32)
RS485.begin(9600, SERIAL_8N1, RX_PIN, TX_PIN);
#else
RS485.begin(9600);
#endif
RS485.setTimeout(1000);
}
void loop() {
uint8_t data[2 * 10];
if (!readRegisters(0x03, 0x0000, 10, data)) {
Serial.println("no reply");
delay(5000);
return;
}
Serial.print("conductivity_ms_cm=");
Serial.print(float32(data[2], data[3], data[0], data[1]), 3);
Serial.print(" resistivity_ohm_cm=");
Serial.print(float32(data[6], data[7], data[4], data[5]), 1);
Serial.print(" temperature_c=");
Serial.print(float32(data[10], data[11], data[8], data[9]), 1);
Serial.print(" tds_ppm=");
Serial.print(float32(data[14], data[15], data[12], data[13]), 1);
Serial.print(" salinity_ppm=");
Serial.print(float32(data[18], data[19], data[16], data[17]), 1);
Serial.println();
delay(5000);
} What the examples read
Both examples send one request, function 0x03, 10 registers from 0x0000, and decode these values:
| Value | Unit | Register | Encoding |
|---|---|---|---|
conductivity_ms_cm | mS/cm | 0x0000 | 32-bit float in two registers, low word first |
resistivity_ohm_cm | Ω·cm | 0x0002 | 32-bit float in two registers, low word first |
temperature_c | °C | 0x0004 | 32-bit float in two registers, low word first |
tds_ppm | ppm | 0x0006 | 32-bit float in two registers, low word first |
salinity_ppm | ppm | 0x0008 | 32-bit float in two registers, low word first |
Other Modbus tools
The same request works from any Modbus RTU master: pymodbus, minimalmodbus, Node-RED, LabVIEW, a PLC or a third-party data logger with a Modbus port. Use the serial settings, function code and register addresses above.
Logging without writing code
The Omni Genesis controller reads the EC-120 and sends the readings to the Agrinovo cloud over the cellular network, where they can be exported or read through the cloud API.
Datasheet reference
Specifications
| Parameter | Specification |
|---|---|
| Conductivity Range | 0 to 200,000 µS/cm (0 to 200 mS/cm) |
| Salinity Range | 0.00 to 100.00 ppt |
| Accuracy | ±1.5% FS |
| Measured Values | Conductivity, resistivity, temperature, TDS, salinity |
| Temperature Compensation | 0 to 60°C (automatic) |
| Operating Temperature | 0 to 60°C |
| Operating Humidity | ≤85% RH |
| Electrode Constant | K = 10.0 |
| Electrode Material | Graphite |
| Body Material | PTFE |
| Output | RS485 Modbus-RTU and 4 to 20mA |
| Supply Voltage | 7 to 24 VDC (12 to 24 VDC when the 4 to 20mA output is used) |
| Power Consumption | ≤0.5 W |
Communication Settings
| Parameter | Value |
|---|---|
| Protocol | Modbus-RTU |
| Baud Rate | 9600 bps |
| Data Bits | 8 |
| Parity | None |
| Stop Bits | 1 |
| Default Address | 0x01 |
Register Map
Measurement Registers (Function 0x03)
Every value is a 32-bit IEEE-754 float held in two registers, low word first.
| Address | Description | Unit |
|---|---|---|
| 0x0000 to 0x0001 | Conductivity | mS/cm |
| 0x0002 to 0x0003 | Resistivity | Ω·cm |
| 0x0004 to 0x0005 | Temperature | °C |
| 0x0006 to 0x0007 | TDS | ppm |
| 0x0008 to 0x0009 | Salinity | ppm (÷ 1000 for ppt) |
Configuration Registers (Function 0x06)
| Address | Description |
|---|---|
| 0x0014 | Slave Address |
Reading Data
Read 10 registers from 0x0000:
Request: 01 03 00 00 00 0A C5 CD
Response: 01 03 14 08 12 3E A2 7E 0F 45 45 A2 B1 41 DD 3B E2 43 1E 0E AC 43 2E F8 F6
Decoding: swap the two 16-bit words of each value, then read the result as a float. Conductivity arrives as 08 12 3E A2, which becomes 3E A2 08 12 = 0.316.
| Value | Received | Swapped | Result |
|---|---|---|---|
| Conductivity | 08 12 3E A2 | 3E A2 08 12 | 0.316 mS/cm |
| Resistivity | 7E 0F 45 45 | 45 45 7E 0F | 3159.9 Ω·cm |
| Temperature | A2 B1 41 DD | 41 DD A2 B1 | 27.7°C |
| TDS | 3B E2 43 1E | 43 1E 3B E2 | 158.2 ppm |
| Salinity | 0E AC 43 2E | 43 2E 0E AC | 174.1 ppm (0.174 ppt) |
Address Configuration
Change Address (0x01 to 0x02)
Write the new address to register 0x0014:
01 06 00 14 00 02 48 0F
Broadcast Discovery
Use address 0xFF with only one device connected. The sensor replies with its own address.
FF 03 00 00 00 0A D0 13
Revision History
| Rev | Date | Changes |
|---|---|---|
| 1.0 | February 2026 | Initial release |
| 2.0 | October 2026 | New sensor generation: graphite electrode, 0 to 100 ppt salinity range, float32 register map, 4 to 20mA output |
| 2.1 | October 2026 | New layout |
Contact
Agrinovo, https://agrinovo.io/products, [email protected], +972 54 688 8148 (direct / WhatsApp). Specifications subject to change without notice.
Questions about wiring or the protocol?
Tell us which board or logger you are using and what you need to measure.