• Agrinovo

Frost Alarm for Orchards and Vineyards: A Setup Guide

How to set up a frost alarm for orchards and vineyards: radiation and advection frost, sensor height and placement, critical bud temperatures and phone alerts.

frost alarm frost protection vineyard orchard temperature monitoring remote monitoring critical temperatures
Grower in a woollen hat bending over a pruned grapevine to check its young buds at sunrise, hoarfrost on the trellis wires, posts and grass between the rows

A frost night is decided in a few hours, usually the last ones before sunrise, and the reading that decides it is the one at bud height in the coldest corner of your own block. The forecast tells you a frost night is coming. It does not tell you which block will reach the damaging temperature, or when. A frost alarm is there to answer those two questions while you are asleep, early enough to act.

Two kinds of frost, two kinds of night

The FAO frost protection manual separates two kinds of frost, and the difference shapes the whole alarm setup.

  • Radiation frost comes with a clear sky, calm or very light wind, a temperature inversion and a low dew point. The ground and plants radiate heat to the sky, the air close to them cools fastest, and cold air drains downhill. By day the air goes back above 0°C. This is the common frost in most fruit regions, and the one where local measurement pays off most.
  • Advection frost arrives when cold air blows in and replaces warmer air. It comes with cloud, moderate to strong wind and no inversion, and the temperature can stay below 0°C through the day. The whole landscape cools together, and methods that depend on an inversion, such as wind machines, do not help.

On a radiation night the air is layered. The FAO manual puts the top of the inversion, its ceiling, usually between 9 and 60 metres above the ground, with the coldest air at the bottom. That layering is why two sensors a few hundred metres apart, or a metre apart in height, can read quite differently on the same night.

Why the forecast and the nearest station are not enough

Standard weather stations measure air temperature in a shelter 1.25 to 2 metres above the ground. On a radiation night that is above the coldest layer, and the FAO manual notes that bud and leaf temperatures are likely to be lower than the shelter temperature. A regional station may also sit on a slope or a hilltop while your block sits in a hollow where cold air collects. The FAO manual’s advice on siting new orchards makes the same point from the other side: avoid low spots where cold air ponds, and ground that dams the cold air drainage.

So the alarm has to measure in your block, at the right height, in the right spot. A forecast is still useful: it tells you which nights to watch. The OmniCloud dashboard’s weather card flags frost-risk nights from the forecast. The sensor in the block tells you what is actually happening there.

Where the sensor goes

Height. The FAO manual’s guidance on frost monitoring is direct: thermometers should be placed at the lowest height where protection is desired, lower in short dense crops and higher in tall sparse ones. Rutgers Cooperative Extension puts it as a rule of thumb: the sensor should be no higher off the ground than the lowest flower bud. In a vineyard trained on a low wire, that is close to the ground; in an orchard, at the height of the lowest scaffold branches carrying blossoms.

Location. Start with the low spots, where cold air drains and collects. Then add one point in every block that behaves differently, such as a young planting, a different variety or a different exposure, and keep one reference point in a block you know well. Keep sensors away from buildings and water, which hold heat, and away from heaters or other protection that would warm them directly.

Shielding. On a clear night an exposed sensor exchanges radiation with the sky and reads something other than the air temperature. Mount it in a ventilated radiation shield. The FAO manual names the Stevenson screen, the fruit-frost shelter and the Gill shield as standard options.

A second height, if you run wind machines. Wind machines work by pulling warmer air down from the inversion, so they only help when the inversion is strong. The FAO manual advises checking, before buying, that the inversion between 2 and 10 metres is at least 1.5°C on most frost nights, and notes that the gain at 2 metres is about 30% of that difference. It does not recommend them in winds above about 2.5 m/s. A second sensor higher up on the same mast shows you the inversion on every frost night, which tells you whether starting the machines will help tonight.

With the THS-100 temperature and humidity sensor, each sensor has its own Modbus address and several share one RS-485 cable, so a low point and a high point on the same mast, or two blocks along one cable, connect to a single controller.

Which temperature to alarm on

A bud’s tolerance to cold depends on its stage. Dormant buds survive far lower temperatures than open blossoms, so the right alarm limit moves through the spring. The standard reference is the critical temperature table: the temperature at which 10% of buds are killed (T10) and the temperature at which 90% are killed (T90), stage by stage.

Values from the Michigan State University Extension chart, based on Washington State University research, and from Washington State University bulletin EB1615 for Concord grapes:

Crop Stage 10% kill 90% kill
Apple Silver tip -9.4°C (15°F) -16.7°C (2°F)
Apple Green tip -7.8°C (18°F) -12.2°C (10°F)
Apple Tight cluster -2.8°C (27°F) -6.1°C (21°F)
Apple First pink -2.2°C (28°F) -4.4°C (24°F)
Apple Full bloom -2.2°C (28°F) -3.9°C (25°F)
Peach Calyx red -5.0°C (23°F) -12.8°C (9°F)
Peach First bloom -3.3°C (26°F) -6.1°C (21°F)
Peach Full bloom -2.8°C (27°F) -4.4°C (24°F)
Sweet cherry Side green -5.6°C (22°F) -12.8°C (9°F)
Sweet cherry Open cluster -2.8°C (27°F) -6.1°C (21°F)
Sweet cherry Full bloom -2.2°C (28°F) -3.9°C (25°F)
Grape (Concord) Full swell -6.1°C (21°F) -12.2°C (10°F)
Grape (Concord) Bud burst -3.9°C (25°F) -8.9°C (16°F)
Grape (Concord) First leaf -2.8°C (27°F) -6.1°C (21°F)
Grape (Concord) Fourth to fifth leaf -2.2°C (28°F) -2.8°C (27°F)

The °F values are as published; the °C values are converted. The WSU bulletin notes that its grape values were set in the laboratory and have not been checked extensively against field injury, and other varieties differ, so treat any table as a starting point for your own blocks.

Three rules turn the table into an alarm limit:

  • Set the alarm above T10, not at it. The alarm has to fire while there is still time to start the protection and for it to take effect.
  • Leave room for your method. If you protect with over-plant sprinklers, the starting point is not the air temperature but the wet-bulb temperature, which depends on the dew point. The FAO manual recommends an alarm about 1°C above the air temperature at which sprinklers should start. Our guide to wet-bulb and dew point on frost nights works through the numbers.
  • Move the limit with the buds. Limits in OmniCloud are set per sensor and can be changed at any time, so raise them as the blocks move from swollen bud to bloom.

Getting the alarm to someone at 3 a.m.

A frost alarm is only as good as the person it wakes. In OmniCloud, an alert goes to the users on the account as a push notification on the phone, through the Agrinovo app. Each user can set quiet hours, and a sensor marked as critical comes through them. That is the setting for frost sensors in the frost season.

An open alert repeats until someone acknowledges it, every two hours by default, and the reminder interval can be shortened for the frost season. When the temperature climbs back above the limit after sunrise, a recovery notice follows. Name every sensor by block and position, such as “Block 4, low corner, 50 cm”, so the alert tells you where to go without opening a map.

Power and signal in the field

A frost sensor sits in the middle of a block, usually far from mains power and Wi-Fi. The Omni Genesis controller is built for that: two rechargeable 18650 batteries, a solar input, 4G-LTE with a SIM included, an IP65 enclosure and an operating range of -20 to +70°C. It stores readings locally and syncs them when the connection returns. If a sensor is disconnected or shorted, the controller reports a fault instead of a plausible temperature, and a controller that stops reporting raises its own offline alert, so a silent station is never mistaken for a warm night.

Our cranberry frost case study shows the whole station on one stake in the bed: controller, small solar panel, an SHT30 temperature and humidity sensor at canopy height, and tensiometers in the soil below, all on the same controller.

From alarm to action

Most growers start their frost protection by hand when the alarm rings. Where the response is always the same, the controller can take the first step. Each of the Genesis controller’s four ports can work as a sensor input or as a switched 12 V or 5 V output, and that output usually drives an external relay that switches a valve, a fan or a heater. The rule runs on the controller itself, from its own readings, so it holds even if the cellular connection drops on the night it matters. If the valve feeds over-plant sprinklers, set the rule with the wet-bulb in mind, not the air temperature alone.

A frost alarm checklist

Decision What to set
Frost type Radiation nights: local sensors decide; advection nights: the whole farm cools together
Height The lowest buds you want to protect, in a ventilated radiation shield
Location Low spots first, one point per block that behaves differently, one reference block
Second height Where wind machines are used, to read the inversion
Alarm limit Above T10 for the current stage, with margin for your method; moved as buds develop
Sprinkler blocks Alarm about 1°C above the sprinkler start temperature for the night’s dew point
Who is woken Frost sensors marked critical, reminder interval shortened for the season
System health Sensor fault, controller offline and low battery alerts on
Testing Before the season: force an alarm, confirm the phones, check each sensor against a reference near 0°C

For other sites on the farm that need a temperature alarm, such as pump houses, greenhouses and barns, see our guide to cellular temperature alarms for remote farm sites.

Frequently asked questions

At what temperature should a frost alarm be set?

Above the critical temperature of the crop at its current stage, with enough margin to start your protection in time. Critical temperatures change as buds develop: Washington State University data put the 10% kill point for apple at -9.4°C at silver tip and -2.2°C from first pink to post bloom. If you protect with sprinklers, the FAO frost manual suggests an alarm about 1°C above the air temperature at which the sprinklers should start, which depends on the dew point.

How high should a frost sensor be mounted?

At the lowest height you want to protect. The FAO frost manual says thermometers should be placed at the lowest height where protection is desired, and Rutgers Cooperative Extension advises that the sensor be no higher off the ground than the lowest flower bud. Mount it in a ventilated radiation shield, away from buildings, water and heaters.

Why does my block read colder than the nearest weather station?

Weather stations measure in a shelter at 1.25 to 2 m, and on a clear, calm night the air near the ground is colder than the air above it. Cold air also drains downhill and collects in low ground. The FAO manual notes that bud and leaf temperatures are likely to be lower than the shelter temperature, so the reading that matters is the one at bud height in your own coldest block.

How many frost sensors does a vineyard or orchard need?

One in every block that behaves differently, starting with the low spots where cold air collects, and a reference point in a block you know well. With the RS-485 THS-100, several sensors share one cable to a single controller, and each controller has four ports, so a farm grows point by point rather than system by system.

Does a frost alarm work in the field without power or Wi-Fi?

Yes. The Omni Genesis controller runs on two rechargeable 18650 batteries with a solar input, reports over 4G-LTE with a SIM included, and is rated for -20 to +70°C in an IP65 enclosure. It stores readings locally and syncs them when the connection returns.

Talk to us about your fields

Tell us the crop, the soil and how many irrigation zones need sensing and we will scope the stations with you.