DO-110 with Arduino, ESP32, Raspberry Pi and Python
How to wire the DO-110 Fluorescent Dissolved Oxygen Sensor (Titanium) to your own microcontroller or computer and read it over RS485 Modbus RTU. The tables are the ones in the datasheet, and both code examples are run against the datasheet example frame before this page is published.
Product page Datasheet (PDF) Datasheet (Markdown) Arduino sketch (.ino) Python script (.py)
Connecting the DO-110
The probe is an RS485 device, so it needs a transceiver between it and your board. On a computer or a Raspberry Pi that is a USB to RS485 adapter. On a microcontroller it is a MAX485-type module on a hardware serial port. Power the probe from a supply within the voltage range in the table and join its ground to the ground of the transceiver.
| Wire Color | Function | Description |
|---|---|---|
| Black | V- | Power Ground (12-24V DC-) |
| Red | V+ | Power Supply (12-24V DC+) |
| Yellow/White | RS485-A | Data+ |
| Green | RS485-B | Data- |
Note: If your RS485 transceiver labels A/B opposite, swap the connections.
Python example (Raspberry Pi, Linux, macOS, Windows)
The script needs only pyserial. It builds the Modbus request itself, checks the CRC of the reply and prints one reading every five seconds. On Windows pass the COM port as the argument.
#!/usr/bin/env python3
"""Read the Agrinovo DO-110 over RS485 Modbus RTU.
Works on a Raspberry Pi or any computer with a USB to RS485 adapter.
Install the serial library once: pip install pyserial
Run: python3 do_110.py /dev/ttyUSB0
"""
import struct
import sys
import time
import serial
PORT = sys.argv[1] if len(sys.argv) > 1 else "/dev/ttyUSB0"
ADDRESS = 0x01 # the sensor's Modbus address
def crc16(frame: bytes) -> bytes:
crc = 0xFFFF
for byte in frame:
crc ^= byte
for _ in range(8):
crc = (crc >> 1) ^ 0xA001 if crc & 1 else crc >> 1
return struct.pack("<H", crc)
def read_registers(port, address, function, start, count):
request = struct.pack(">BBHH", address, function, start, count)
port.reset_input_buffer()
port.write(request + crc16(request))
reply = port.read(5 + 2 * count)
if len(reply) >= 5 and reply[1] == function | 0x80:
raise IOError(f"sensor returned Modbus error {reply[2]}")
if len(reply) != 5 + 2 * count or crc16(reply[:-2]) != reply[-2:]:
raise IOError("no valid reply from the sensor")
return reply[3:-2]
def read_probe(port):
data = read_registers(port, ADDRESS, 0x03, 0x0000, 4)
return {
"dissolved_oxygen": struct.unpack("<f", data[0:4])[0], # mg/L
"temperature": struct.unpack("<f", data[4:8])[0], # °C
}
if __name__ == "__main__":
with serial.Serial(PORT, 9600, bytesize=8, parity="N", stopbits=1, timeout=1) as port:
while True:
print(read_probe(port))
time.sleep(5) Arduino example (Uno, Mega, ESP32, ESP8266, MKR, Pico)
The sketch uses the Agrinovo library: in the Arduino IDE open Sketch > Include Library > Manage Libraries and install "Agrinovo". The library picks the serial port for your board, and the pins are listed at the top of AgrinovoDefaultPort.h. DE and RE of the transceiver go to one output pin.
// Agrinovo DO-110 dissolved oxygen probe
// Prints dissolved oxygen and temperature every 5 seconds.
//
// Sensor cable
// Red supply +, 12-24 V DC
// Black supply ground, joined to the board's ground
// Yellow or white RS485 A
// Green RS485 B
//
// The board talks to the sensor through an RS485 transceiver (MAX485 or
// similar). AgrinovoDefaultPort.h lists the serial pins used on each board.
//
// https://agrinovo.io/products/sensors/aqua/do/do-110-titanium-probe/
#include <Agrinovo.h>
#include <AgrinovoDefaultPort.h>
const int DE_PIN = 4; // transceiver DE and RE, tied together
AgrinovoBus bus(AGRINOVO_PORT, DE_PIN);
AgrinovoDO110 probe(bus); // Modbus address 1
void setup() {
Serial.begin(115200);
agrinovoPortBegin(9600);
bus.begin();
}
void loop() {
if (probe.read()) {
Serial.print("Dissolved oxygen: ");
Serial.print(probe.dissolvedOxygen(), 2);
Serial.println(" mg/L");
Serial.print("Temperature: ");
Serial.print(probe.temperature(), 2);
Serial.println(" °C");
} else {
Serial.println(probe.errorText());
}
delay(5000);
} What the examples read
Both examples send one request, function 0x03, 4 registers from 0x0000, and decode these values:
| Value | Unit | Register | Encoding |
|---|---|---|---|
| Dissolved oxygen | mg/L | 0x0000 | 32-bit float, least significant byte first |
| Temperature | °C | 0x0002 | 32-bit float, least significant byte first |
Other Modbus tools
The same request works from any Modbus RTU master: pymodbus, minimalmodbus, Node-RED, LabVIEW, a PLC or a third-party data logger with a Modbus port. Use the serial settings, function code and register addresses above.
Logging without writing code
The Omni Genesis controller reads the DO-110 and sends the readings to the Agrinovo cloud over the cellular network, where they can be exported or read through the cloud API.
Datasheet reference
Specifications
| Parameter | Specification |
|---|---|
| DO Range | 0 to 20 mg/L |
| Temperature Range | 0 to 50°C |
| Protection Rating | IP68 |
| Supply Voltage | 12-24 VDC |
Compensation
| Type | Method |
|---|---|
| Temperature | Automatic |
| Salinity | Manual input (ppt) |
| Pressure | Manual input (kPa) |
Communication Settings
| Parameter | Value |
|---|---|
| Protocol | Modbus-RTU |
| Baud Rate | 9600 bps |
| Data Bits | 8 |
| Parity | None |
| Stop Bits | 1 |
| Default Address | 0x01 |
Register Map
Data Encoding
DO and Temperature values are float32 in little-endian byte order.
Measurement Registers (Function 0x03)
| Address | Registers | Description |
|---|---|---|
| 0x0000 | 4 | DO (float32) + Temperature (float32) |
| 0x000A | 2 | Production Serial Number |
| 0x0010 | 1 | Slave Address (via 0xFF request) |
| 0x0011 | 2 | Field Calibration Parameter |
| 0x0062 | 1 | Salinity (ppt, integer) |
Configuration Registers (Function 0x10)
| Address | Description | Notes |
|---|---|---|
| 0x0010 | Set Slave Address | Range: 1 to 247 |
| 0x0011 | Field Calibration | Pressure in 0.01 kPa |
| 0x0021 | Cancel Field Calibration | Write 0x1400 |
| 0x0062 | Set Salinity | Value in ppt |
Reading Data
Read DO + Temperature (Float)
Read 4 registers from 0x0000:
Request: 01 03 00 00 00 04 44 09
Response: 01 03 08 48 E1 0A 41 F6 28 B4 41 59 5A
Decoding (Little-endian float32):
| Value | Bytes Received | Reordered | Result |
|---|---|---|---|
| DO | 48 E1 0A 41 | 41 0A E1 48 | 8.68 mg/L |
| Temperature | F6 28 B4 41 | 41 B4 28 F6 | 22.52°C |
Address Configuration
Read Current Address (Using 0xFF)
Request: FF 03 00 10 00 01 90 11
Response: FF 03 02 03 00 91 60
Response shows current address = 0x03
Set New Address
Write to 0x0010 using function 0x10:
01 10 00 10 00 01 02 14 00 AB C0
Calibration
Field Calibration (Pressure)
Place probe in air-saturated DO, wait for stability. Write pressure to 0x0011.
Pressure: kPa × 100 (e.g., 101.33 kPa = 10133 = 0x2795)
01 10 00 11 00 01 02 95 27 8A 5B
Cancel Field Calibration
Write 0x1400 to register 0x0021:
01 10 00 21 00 01 02 14 00 AF E1
Maintenance
- Calibration interval depends on the water type and the amount of biofouling and algae. Under normal conditions, calibrate every 6-8 months.
- Clean the membrane cap regularly between calibrations.
- The membrane cap is replaceable, typically after 2+ years of use.
Revision History
| Rev | Date | Changes |
|---|---|---|
| 1.0 | June 2026 | Initial release |
| 1.1 | August 2026 | Layout revision |
| 1.2 | October 2026 | New layout |
Contact
Agrinovo, https://agrinovo.io/products, [email protected], +972 54 688 8148 (direct / WhatsApp). Specifications subject to change without notice.
Questions about wiring or the protocol?
Tell us which board or logger you are using and what you need to measure.