O2-100 with Arduino, ESP32, Raspberry Pi and Python
How to wire the O2-100 Soil Oxygen Sensor to your own microcontroller or computer and read it over RS485 Modbus RTU. The tables are the ones in the datasheet, and both code examples are run against the datasheet example frame before this page is published.
Connecting the O2-100
The probe is an RS485 device, so it needs a transceiver between it and your board. On a computer or a Raspberry Pi that is a USB to RS485 adapter. On a microcontroller it is a MAX485-type module on a hardware serial port. Power the probe from a supply within the voltage range in the table and join its ground to the ground of the transceiver.
| Wire Color | Function | Description |
|---|---|---|
| Red | V+ | Power Supply (7-24V DC) |
| Black | GND | Power Ground |
| Yellow | RS485-A | Data+ |
| Green | RS485-B | Data- |
Python example (Raspberry Pi, Linux, macOS, Windows)
The script needs only pyserial. It builds the Modbus request itself, checks the CRC of the reply and prints one reading every five seconds. On Windows pass the COM port as the argument.
#!/usr/bin/env python3
"""Read the Agrinovo O2-100 over RS485 Modbus RTU.
Works on a Raspberry Pi or any computer with a USB to RS485 adapter.
Install the serial library once: pip install pyserial
Run: python3 o2_100.py /dev/ttyUSB0
"""
import struct
import sys
import time
import serial
PORT = sys.argv[1] if len(sys.argv) > 1 else "/dev/ttyUSB0"
ADDRESS = 0x01 # the probe's Modbus address
def crc16(frame: bytes) -> bytes:
crc = 0xFFFF
for byte in frame:
crc ^= byte
for _ in range(8):
crc = (crc >> 1) ^ 0xA001 if crc & 1 else crc >> 1
return struct.pack("<H", crc)
def read_registers(port, address, function, start, count):
request = struct.pack(">BBHH", address, function, start, count)
port.reset_input_buffer()
port.write(request + crc16(request))
reply = port.read(5 + 2 * count)
if len(reply) >= 5 and reply[1] == function | 0x80:
raise IOError(f"probe returned Modbus error {reply[2]}")
if len(reply) != 5 + 2 * count or crc16(reply[:-2]) != reply[-2:]:
raise IOError("no valid reply from the probe")
return reply[3:-2]
def read_probe(port):
data = read_registers(port, ADDRESS, 0x03, 0x0000, 1)
return {
"oxygen_pct_vol": struct.unpack(">H", data[0:2])[0] * 0.1,
}
if __name__ == "__main__":
with serial.Serial(PORT, 9600, bytesize=8, parity="N", stopbits=1, timeout=1) as port:
while True:
print(read_probe(port))
time.sleep(5) Arduino example (ESP32, Mega and other boards with a second serial port)
The sketch uses no library. On an ESP32 it uses Serial2 on the pins set at the top; on AVR boards it uses Serial1. DE and RE of the transceiver go to one output pin.
// Agrinovo O2-100 over RS485 Modbus RTU.
// For a board with a spare hardware serial port (ESP32, Mega, Leonardo, Due)
// and a MAX485-type transceiver. Power the probe from its own supply, as the
// wiring table says, and join the grounds.
const uint8_t ADDRESS = 0x01; // the probe's Modbus address
const int DE_PIN = 4; // transceiver DE and RE tied together
const int RX_PIN = 16; // ESP32 only
const int TX_PIN = 17; // ESP32 only
#if defined(ESP32)
#define RS485 Serial2
#else
#define RS485 Serial1
#endif
uint16_t crc16(const uint8_t *frame, size_t length) {
uint16_t crc = 0xFFFF;
for (size_t i = 0; i < length; i++) {
crc ^= frame[i];
for (int bit = 0; bit < 8; bit++) {
crc = (crc & 1) ? (crc >> 1) ^ 0xA001 : crc >> 1;
}
}
return crc;
}
uint16_t word16(const uint8_t *b) {
return ((uint16_t)b[0] << 8) | b[1];
}
// Reads `count` registers into `data`. Returns false when the probe does not
// answer or the checksum is wrong.
bool readRegisters(uint8_t function, uint16_t start, uint16_t count, uint8_t *data) {
uint8_t request[8] = {ADDRESS, function, (uint8_t)(start >> 8), (uint8_t)start,
(uint8_t)(count >> 8), (uint8_t)count, 0, 0};
uint16_t crc = crc16(request, 6);
request[6] = crc & 0xFF;
request[7] = crc >> 8;
while (RS485.available()) RS485.read();
digitalWrite(DE_PIN, HIGH);
RS485.write(request, 8);
RS485.flush();
digitalWrite(DE_PIN, LOW);
uint8_t reply[5 + 2 * 16];
size_t expected = 5 + 2 * count;
if (RS485.readBytes(reply, expected) != expected) return false;
uint16_t received = reply[expected - 2] | ((uint16_t)reply[expected - 1] << 8);
if (reply[1] != function || crc16(reply, expected - 2) != received) return false;
memcpy(data, reply + 3, 2 * count);
return true;
}
void setup() {
Serial.begin(115200);
pinMode(DE_PIN, OUTPUT);
digitalWrite(DE_PIN, LOW);
#if defined(ESP32)
RS485.begin(9600, SERIAL_8N1, RX_PIN, TX_PIN);
#else
RS485.begin(9600);
#endif
RS485.setTimeout(1000);
}
void loop() {
uint8_t data[2 * 1];
if (!readRegisters(0x03, 0x0000, 1, data)) {
Serial.println("no reply");
delay(5000);
return;
}
Serial.print("oxygen_pct_vol=");
Serial.print(word16(data + 0) * 0.1f, 1);
Serial.println();
delay(5000);
} What the examples read
Both examples send one request, function 0x03, 1 registers from 0x0000, and decode these values:
| Value | Unit | Register | Encoding |
|---|---|---|---|
oxygen_pct_vol | %VOL | 0x0000 | Unsigned 16-bit integer, scaled |
Other Modbus tools
The same request works from any Modbus RTU master: pymodbus, minimalmodbus, Node-RED, LabVIEW, a PLC or a third-party data logger with a Modbus port. Use the serial settings, function code and register addresses above.
Logging without writing code
The Omni Genesis controller reads the O2-100 and sends the readings to the Agrinovo cloud over the cellular network, where they can be exported or read through the cloud API.
Datasheet reference
Specifications
| Parameter | Specification |
|---|---|
| Measured Parameter | Oxygen concentration |
| Range | 0-25 %VOL |
| Resolution | 0.1 %VOL |
| Accuracy | ±2% FS (at 25°C) |
| Repeatability | ≤1% FS |
| Temperature Drift | 0.2% FS per °C |
| Response Time | Under 15 seconds |
| Sensing Method | Electrochemical cell with temperature compensation |
Electrical Characteristics
| Parameter | Specification |
|---|---|
| Supply Voltage | 7-24 VDC |
| Average Current | ≤15 mA |
| Operating Temperature | -20°C to 50°C |
| Operating Humidity | 15-80% RH (non-condensing) |
| Dimensions | 97 mm length, 30 mm diameter |
Caution: Connect the sensor with correct polarity and within the rated supply voltage. Reverse polarity or overvoltage will permanently damage the sensing cell.
Communication Settings
| Parameter | Value |
|---|---|
| Protocol | Modbus-RTU |
| Baud Rate | 9600 bps |
| Data Bits | 8 |
| Parity | None |
| Stop Bits | 1 |
| Default Address | 0x01 |
Register Map
Measurement Register (Function 0x03)
| Address | Description | Scaling |
|---|---|---|
| 0x0000 | Oxygen Concentration | Value ÷ 10 = %VOL |
Address Configuration (Function 0x06)
| Address | Description | Range |
|---|---|---|
| 0x0000 | Slave Address | 0x01-0xFE |
The oxygen value is read from register 0x0000 with function 0x03. The slave address is changed by writing the new address to register 0x0000 with function 0x06.
Reading Data
Read 1 register from 0x0000 (function 0x03):
Request: 01 03 00 00 00 01 84 0A
Response: 01 03 02 00 D1 78 18
Decoding:
| Register | Hex | Decimal | Scaling | Result |
|---|---|---|---|---|
| 0x0000 Oxygen | 0x00D1 | 209 | ÷ 10 | 20.9 %VOL |
Address Configuration
Change Address (0x01 to 0x02)
Write the new address to register 0x0000 with function 0x06:
Request: 01 06 00 00 00 02 08 0B
Power cycle the sensor after changing the address.
Broadcast Discovery
Use address 0xFE with only one device connected to query an unknown address.
Revision History
| Rev | Date | Changes |
|---|---|---|
| 1.0 | June 2026 | Initial release |
| 1.1 | August 2026 | Layout revision |
| 1.2 | October 2026 | New layout |
Contact
Agrinovo, https://agrinovo.io/products, [email protected], +972 54 688 8148 (direct / WhatsApp). Specifications subject to change without notice.
Questions about wiring or the protocol?
Tell us which board or logger you are using and what you need to measure.