Water potential is the potential energy of water per unit volume, compared with pure free water at the same temperature and elevation. Pure water at atmospheric pressure is the zero. Soil water, plant sap and humid air are almost always below zero, and the size of the negative number says how hard something has to pull to take water away.
OpenStax Biology defines it as the difference in potential energy between a given water sample and pure water. Because it is energy per volume, it has the units of pressure, and that is why the same quantity appears as megapascals in plant physiology and as kilopascals or centibars on a field tensiometer.
The water potential formula
Total water potential is the sum of four components:
Ψt = Ψm + Ψs + Ψp + Ψg
| Component | Symbol | Sign | Where it comes from |
|---|---|---|---|
| Matric potential | Ψm | Zero or negative | Water held on soil particles and in pores by adhesion and capillarity |
| Solute (osmotic) potential | Ψs | Zero or negative | Dissolved salts and sugars |
| Pressure potential | Ψp | Positive or negative | Hydrostatic pressure: turgor in a cell, depth below a water table |
| Gravitational potential | Ψg | Depends on the reference height | Position in the gravity field |
OpenStax writes the same sum as Ψtotal = Ψs + Ψp + Ψg + Ψm. The soil physics text by Tyson Ochsner treats matric potential as the part of the pressure potential that comes from the soil’s solid matrix.
Matric potential (Ψm)
In unsaturated soil, water clings to particle surfaces and sits in small pores. Pulling it out takes work, so Ψm is negative. It is 0 kPa in saturated soil and falls far below -1500 kPa in a dry surface soil. Irrigation people usually drop the sign and call the same number soil water tension or suction: a matric potential of -30 kPa is a tension of 30 kPa.
Solute potential: Ψs = -iCRT
Dissolved solutes lower the potential of water. For a dilute solution the van ‘t Hoff relation gives:
Ψs = -iCRT
- i is the van ‘t Hoff factor, the number of particles each formula unit releases in solution (1 for sucrose, 2 for NaCl)
- C is the molar concentration in mol/L
- R is the gas constant, 0.008314 L·MPa/(mol·K)
- T is the temperature in kelvin
Worked example. A 0.1 mol/L sodium chloride solution at 25°C (298 K):
Ψs = -(2 × 0.1 × 0.008314 × 298) = -0.50 MPa
That is about -500 kPa. The same concentration of sucrose, with i = 1, gives -0.25 MPa. OpenStax gives typical values for cell cytoplasm of -0.5 to -1.0 MPa.
In soil, the solute term matters most where salts build up. A root sees the sum of matric and solute potential, so a saline soil can be wet and still hard to draw water from.
Pressure potential (Ψp)
Below a water table, the weight of the water above adds a positive pressure of about 9.8 kPa for every metre of depth. Inside a plant cell the same term is turgor, which OpenStax puts at around 0.6 to 0.8 MPa in a well-watered plant.
Gravitational potential (Ψg)
Ψg = ρ × g × h
With the density of water ρ = 1,000 kg/m³ and g = 9.81 m/s², every metre of height above the reference level adds 9.8 kPa. Over the depth of a root zone the term is small next to matric potential in a drying soil. In wet soil it is the one that drives drainage.
Water potential units and conversions
The University of New Hampshire’s soil moisture sensor fact sheet gives the first two equalities in one line: 1 kPa = 1 centibar, and 100 centibars = 1 bar. Ochsner’s text gives the head conversion: 1 kPa = 10.2 cm of water.
| Unit | Relation to kPa | Field capacity (-33 kPa) | Wilting point (-1500 kPa) |
|---|---|---|---|
| kPa | 1 | 33 | 1,500 |
| Centibar (cb) | 1 cb = 1 kPa | 33 | 1,500 |
| Bar | 1 bar = 100 kPa | 0.33 | 15 |
| MPa | 1 MPa = 1,000 kPa | 0.033 | 1.5 |
| cm of water | 1 kPa = 10.2 cm | 337 | 15,300 |
| pF | log10 of the tension in cm of water | 2.5 | 4.2 |
The table lists tensions, the positive form of the number. pF is a logarithmic scale; the University of British Columbia soil lab notes define it as the log of the tension in hectopascals, which is within 2% of a centimetre of water.
To convert a reading without the arithmetic, use the water potential calculator.
Why water moves from high to low potential
Water flows toward lower potential, and the rate depends on how steep the drop is. Transpiration runs on a chain of such drops. OpenStax states the condition for water to reach the leaves: Ψsoil > Ψroot > Ψstem > Ψleaf > Ψatmosphere. Dry air sits at a far lower potential than any living tissue, so water is pulled from the soil through the plant with no pumping by the plant.
The same rule explains what a soil profile does after irrigation. Water in the wet upper layer is at a higher potential than the drier soil below, so it moves down.
Field capacity and wilting point as potentials
Two points on the scale carry names. South Dakota State University Extension defines them this way:
- Field capacity is the water a soil retains once gravity no longer drains it, measured at -10 kPa in sandy soils and -33 kPa in loamy and clay soils.
- Permanent wilting point is the water content at which plants can no longer extract water, measured at -1500 kPa.
Plant available water is the difference between the two. The potentials are conventions chosen so that laboratories measure the same thing. The water contents behind them vary widely: the same SDSU table lists field capacity at 10% water by volume for a sand and 42% for a clay.
Water potential vs water content
Water content is an amount: cubic metres of water per cubic metre of soil. Water potential is an energy state. The two are tied together by the soil water retention curve, and every soil has its own. The New Hampshire fact sheet shows the practical effect: at a tension of 40 kPa, about 50% of the available water remains in a sandy loam and about 35% in a loamy sand.
Irrigation research uses both.
- Potential says whether the plant can take up water and which way water is moving. It transfers between soils: -60 kPa means the same thing to a root in sand and in clay.
- Content says how many millimetres to apply. FAO-56 computes the total available water in the root zone from water contents: TAW = 1000 × (θFC - θWP) × Zr, with Zr the rooting depth in metres.
A retention curve measured on the trial soil lets you move from one to the other, so a water balance kept in millimetres can be checked against a stress threshold set in kPa.
How matric potential is measured
Tensiometers measure it directly. A water-filled tube with a porous ceramic tip is placed in the soil, the soil draws water through the ceramic, and a gauge or transducer reads the vacuum that results. Solutes pass through the ceramic, so a tensiometer reads matric potential and leaves the solute term out. Its range ends at about -80 kPa, according to Ochsner’s text, because below that air enters through the ceramic. Our tensiometer guide covers installation, reading and maintenance.
Granular matrix sensors take an indirect route. Two electrodes sit in a porous matrix that exchanges water with the soil, and the electrical resistance between them rises as the matrix dries. The reading is converted to tension through a calibration, which carries them past the range of a tensiometer into drier soil. The granular matrix sensor guide explains the conversion and the conditioning these sensors need before installation.
Agrinovo sensors for matric potential
Agrinovo supplies four instruments for this measurement. Each one is chosen by the tension range the soil or medium will reach.
| Instrument | Range | Where it fits |
|---|---|---|
| Irrometer SR tensiometer | 0-100 cb (kPa) gauge | Medium to heavy soils; six lengths from 15 to 120 cm |
| Irrometer LT tensiometer | 0-40 cb (kPa) gauge | Coarse and sandy soils and potting soil; six lengths from 15 to 120 cm |
| Irrometer MLT tensiometer | 0-40 cb (kPa) gauge | Small containers and pots; 171 mm overall |
| Watermark 200SS | 0-200 cb (kPa) | Granular matrix sensor; ±15% of reading between 10 and 100 cb |
The tensiometers are read on the gauge. For the SR and LT the manufacturer offers a voltage transducer (0.5 V to 4.5 V) or a 4-20 mA transducer in place of the gauge, which gives a signal for an analog input on a logger or on the Omni Genesis controller.